Hermetic Electrical Feedthroughs Specifications

HERMETIC EPOXY TEMPERATURE RATING (Epoxy is proprietary and not sold separately)
PAVE Wire Seal® 150
PAVE Wire Seal® 200
PAVE Wire Seal® 200UL94VO
-200° to 125° C
-200° to 150° C
-200° to 200° C

-200C may be possible when designed for use with a Teflon o-ring

Any type or size of wire or cable may be specified including coaxial cables, thermocouple wire pairs, high voltage wires, fiber optic cable, flat cables, etc. for length.
NO DETECTABLE LEAKAGE THRU CONDUCTOR OR INSULATION.

Wire Conductor Gage (AWG)
O. D.
Amperage Rating
Nominal Insulation Overall
Nominal Insulation Diameter (O.D.)
30
.30 mm
2
.03
0.8 mm
28
.40
2
.04
1.0
26
.50
3
.05
1.3
24
.60
3
.06
1.75
22
.78
4
.06
1.5
20
.90
6
.07
1.9
18
1.21
8
.08
2.0
16
1.50
10
.09
2.3
14
1.85
18
.11
2.8
12
2.4
25
.12
3.0
10
2.94
40
.21
5.3
6
4.67
80
.26
6.6

PAVE-Seal Epoxy Comparative Tracking Index

Tracking Index (V) PLC
600 or greater
0
400 thru 599
1
250 thru 399
2
175 thru 249
3
100 thru 174
4
<100

The CTI value is used for electrical safety assessment of electrical apparatus, as for instance carried out by Underwriters Laboratory. The minimum required creepage distances over an insulating material between electrically conducting parts in apparatus, especially between parts with a high voltage and parts that can be touched by human users, is dependent on the insulators CTI value. Also for internal distances in an apparatus by maintaining CTI based distances, the risk of fire is reduced. Performance Level Categories (PLC) were introduced to avoid excessive implied precision and bias. — CTI Test Results